Case Report

Radiation Safety Considerations in Hemodialysis Following Lu-177-PSMA-617 Therapy: A Case Report

by Yu-Yi Huang1,3*, Ting-Chum Lin1, Shih-Han Yang1, Lan-Shih Lai2, Ling-Man Hung1, Ming-Hsin Li1, Ching-Yueh Hsia4, Kuo-Cheng Huang5

1Department of Nuclear Medicine, Koo-Foundation Sun Yat-Sen Cancer Center, Taipei, Taiwan

2Hemodialysis room, Department of Internal Medicine, Koo-Foundation Sun Yat-Sen Cancer Center, Taipei, Taiwan

3School of Medicine, College of Medicine, National Yung Ming Chiao Tung University

4Global Medical Solutions, Taipei, Taiwan

5Department of Hematology and Medical Oncology, Koo-Foundation Sun Yat-Sen Cancer Center, Taipei, Taiwan

*Corresponding author: Yu-Yi Huang, Department of Nuclear Medicine, Koo-Foundation Sun Yat-Sen Cancer Center, Taipei, Taiwan

Citation: Huang YY, Lin TC, Yang SH, Lai LS, Hung LM, et al (2024) Radiation Safety Considerations in Hemodialysis Following Lu-177-PSMA-617 Therapy: A Case Report. Ann Case Report. 9: 1828. DOI:10.29011/2574-7754.101828

Received: 24 May 2024, Accepted: 28 May 2024, Published: 30 May 2024

Received Date:

Accepted Date:

Published Date:

Abstract

Purpose: We present a patient who is undergoing regular HD and received Lu-177-PSMA-617 treatment, regarding radiation safety issues including environmental radiation, exposure of medical personnel, and the radioactivity in the dialysate.

Methods: A 78 years old man with metastatic castration-resistant prostate cancer undergoing HD received 84.4 mCi of Lu-177-PSMA-617. First HD during the 20th ~24th hours after injection, and the second HD during 68th ~71st hours. The environmental exposure rate and personnel exposure monitoring were measured. The dialysate was collected and sampled, and the activity was measured.

Results: During the first HD session, where dialysate was collected in the room, medical personnels received exposure of 3~19µSv. Dialysate was drained out in the second HD, and medical personnels received 2~4 µSv. The radiation exposure rates in the first HD were measured as follows: 3~4 µSv/hr bedside, 1.2~1.5 µSv/hr at 1 meter, and less than 0.3 µSv/hr at 4 meters. In the second HD, the rates were 2~3 µSv/hr bedside, 1.2~1.8 µSv/hr at 1 meter, and less than 0.3 µSv/hr at 4 meters. The dialysate had an activity of 6.88 mCi in 120 liters of the first HD, while in the second HD, it had 2.13 mCi in 90 liters.

Conclusion: For the medical personnel involving HD, the accumulative exposure doses were than 2~19 µSv after 20 hour of injection. The environmental exposure rate would drop to background at 4m away from the patient. The dialysate contained minimal amounts of Lu-177 radioactivity.

Keywords: Lu-177-PSMA-617; Hemodialysis; Radiation Safety; Dialysate.

© by the Authors & Gavin Publishers. This is an Open Access Journal Article Published Under Attribution-Share Alike CC BY-SA: Creative Commons Attribution-Share Alike 4.0 International License. With this license, readers can share, distribute, download, even commercially, as long as the original source is properly cited. Read More About Open Access Policy.

Annals of Case Reports